Water Cooling AC switches

Main characteristicsWater-Cooling-AC-switches
Assemblies containing two thyristors connected back to back
Rated Irms current for ED = 100% operations
4 L/min typical water flow rate
Customized busbars connections on request
Customized water connections on request
Single side cooling on request

Water cooled AC switches Water
insulation
VDRM
VRRM
IRMS
Twater
ITSM  I2t
Tjmax
VGT/IGT
Tj=25°C
 VT(TO)
Tjmax
 rT
Tjmax
Rth   Tjmax  Max
water
 Outline
     [V]  [A/°C]  [kA]  [A2•s•103] [V]  [V]  [mΩ]  [°C/W]  [°C]  [bar]  
 2-2W4-P  no  1600  1170/30(1)  8,4  353  3,5 / 200  0,93  0,64  0,1  125  10  Y0
 2-2W5-PI  Al2O3 disks  1600  1275/30(1)  8,4  353  3,5 / 200  0,93  0,64  0,09  125  10  Y0
 2-2WI-600  elastomer  1600  730/40  5,6  157  3,5 / 200  1  0,68  0,25  125  10  W0
 2-2WI-1000  elastomer  1600  1100/40  8,8  387  3,5 / 200  0,91  0,58  0,18  125  10  W0
 2-2WI-1200  elastomer  1600  1290/40  12,5  781  3,5 / 250  1  0,38  0,14  125  10  W0
 2-2W5I-AT505  elastomer  1600  625/40  5,6  157  3,5 / 200  1  0,68  0,3  125  10  W1
 2-2W5I-AT603  elastomer  1600  880/40  8,8  387  3,5 / 200  0,91  0,58  0,21  125  10  W1
 2-2W5I-AT804  elastomer  1600  1120/40  12,5  781  3,5 / 250  1  0,38  0,17  125  10  W1
 2-2W5I-AT1004  elastomer  1600  1550/40  24,6  3026  3,5 / 300  0,92  0,216  0,13  125  10  W1
 2-2W5I-AT636  elastomer  1600  1810/40  36  6480  3,5 / 300  0,82  0,18  0,12  125  10  W1